Section 06 13 00 Heavy Timber Construction
Nova guide specification, CSI SectionFormat. Answer the project questions and the spec rewrites itself: options resolve, unused species drop out, and fire, coastal and warranty requirements follow your choices. Click any [bracket] to choose by hand.
SECTION 06 13 00
HEAVY TIMBER CONSTRUCTION
SPECIFIER NOTEThis guide specification is written in CSI SectionFormat and PageFormat for editing by the design professional. Specifier notes (shaded) and bracketed options [ ]✕ must be edited or deleted before issue. Highlighted items [...]✕ are manufacturer data to be confirmed by Nova USA Wood Products before this document is published.
SPECIFIER NOTEThis section is based on products of Nova USA Wood Products, 3821 24th Avenue, Forest Grove, OR 97116. Tel: (503) 419-6407. Email: sales@novausawood.com. Web: www.novausawood.com. BIM files for rainscreen, decking and clip profiles, profile drawings, installation guides and warranties are at www.novausawood.com/downloads. Technical support, samples and AIA continuing education presentations are available from the manufacturer.
SPECIFIER NOTEThis section covers solid-sawn Douglas fir timbers for posts, beams and exposed structure. Timber design, connections and member sizes are by the Engineer of Record. Where the building is Type IV-HT construction, verify minimum member sizes under IBC Section 2304.11.
SPECIFIER NOTEDouglas fir timbers are not covered by a manufacturer's warranty for exterior use.
PART 1 - GENERAL
1.1SUMMARY
A.Section Includes:
1.Solid-sawn Douglas fir timbers: posts, beams, purlins and stringers.
2.[Exposed timber framing for pergolas, porches and canopies.]✕
B.Related Requirements:
1.Section 05 50 00 "Metal Fabrications" or Section 06 05 23 "Wood, Plastic, and Composite Fastenings" for connectors.
2.Section 06 10 00 "Rough Carpentry."
3.Section 09 93 00 "Staining and Transparent Finishing."
1.2REFERENCES
A.AWC NDS - National Design Specification for Wood Construction and Supplement (design values).
B.WCLIB Standard No. 17 - Grading Rules for West Coast Lumber.
C.ALSC - American Lumber Standard Committee accreditation.
D.International Building Code Section 2304.11 - Heavy Timber Construction.
1.3SUBMITTALS
A.Product Data: Species, grade, sizes, surfacing and moisture condition.
B.Grading Certificates: For each timber, grade stamp, or for members exposed on all faces and ends a certificate of inspection, from an ALSC-accredited agency.
C.Shop Drawings: Member sizes, lengths, cuts, notches and connection locations.
D.Samples: [Surfacing sample showing selected finish.]✕
1.4QUALITY ASSURANCE
A.Grading Agency: ALSC-accredited agency, [Pacific Lumber Inspection Bureau (PLIB)] [West Coast Lumber Inspection Bureau (WCLIB)].
B.Appearance: Exposed timbers to be selected and handled to minimize marking; checking, seasoning splits and color variation are natural characteristics of air-dried timbers and are not defects within grade limits.
1.5DELIVERY, STORAGE, AND HANDLING
A.Store timbers off the ground on level supports, separated by stickers, under breathable cover. Protect exposed timbers from staining, ultraviolet exposure and rain.
B.Handle with nylon slings; do not use chains or forks against exposed faces.
PART 2 - PRODUCTS
2.1MANUFACTURERS
SPECIFIER NOTEChoose ONE of the two options below. Option 1 (basis of design) is recommended for most public and private work: it names Nova while allowing the contractor to propose an equal under Division 01. Use Option 2 (proprietary) only where the Owner permits a sole-source specification.
A.Basis-of-Design Product: Subject to compliance with requirements, provide Douglas fir timbers by Nova USA Wood Products, Forest Grove, Oregon; www.novausawood.com.
1.Comparable Products: Products of other manufacturers will be considered when they meet every performance requirement of this Section, documented by test reports from independent laboratories, and are approved by the Architect in accordance with Section 01 60 00 - Product Requirements.
2.Substitutions: Not permitted.
B.Source Limitations: Obtain timbers [and factory finish]✕ from a single source through one manufacturer.
2.2TIMBERS
A.Species: Douglas fir, Pseudotsuga menziesii.
B.Grade: No. 1 and Better Structural, Free of Heart Center (FOHC), dense fine grain (not less than 6 growth rings per inch), old growth, per WCLIB Standard No. 17, grade-stamped on one end; where members will be exposed on all faces and ends, furnish a certificate of inspection from the grading agency in lieu of stamps. Supply is drawn preferentially from salvage logging.
C.Seasoning: Air dried (AD), not kiln dried; typical moisture content 14 to 18 percent at shipment. Timbers will continue to season, shrink and check in service.
D.Sizes: As indicated on Drawings: nominal 2 x 8, 2 x 10 and 2 x 12, and 4 x 4 through 12 x 12, air-dried (AD), surfaced four sides. Net dimensions: 1/2 inch less than nominal in each direction (e.g., 6 x 12 = 5-1/2 x 11-1/2 inches), per Nova Standard Profiles (www.novausawood.com/standard-profiles; downloadable SVG drawings).
E.Lengths: [8 to 40 feet (2.4 to 12.2 m), even lengths] [Specified lengths, cut to length by manufacturer: ].
F.Surfacing: [Rough sawn] [S4S] [Hand-hewn texture] [Resawn]; [eased edges]✕.
G.Physical Properties (reference): Density 510 kg/m3; shrinkage radial 4.5 percent, tangential 7.3 percent (green to oven dry).
H.Design Values: Per AWC NDS Supplement for Douglas fir-larch timbers of the grade specified.
2.3FINISH
A.[Factory] [Field]-applied finish: [Unfinished] [Nova ExoShield, color , per Section 09 93 00]. Seal end grain with ExoWax.
PART 3 - EXECUTION
3.1INSTALLATION
A.Erect timbers plumb, level and true to line. Fit connections tight; drill holes for bolts 1/16 inch (1.5 mm) oversize.
B.Do not notch, bore or cut members except as indicated on approved Shop Drawings.
C.Seal field-cut ends with ExoWax immediately after cutting.
3.2PROTECTION
A.Protect exposed timbers from weather, staining and damage until enclosed or finished.
END OF SECTION