Section 06 42 00 Wood Paneling

Nova guide specification, CSI SectionFormat. Answer the project questions and the spec rewrites itself: options resolve, unused species drop out, and fire, coastal and warranty requirements follow your choices. Click any [bracket] to choose by hand.

SECTION 06 42 00

WOOD PANELING

SPECIFIER NOTEThis guide specification is written in CSI SectionFormat and PageFormat for editing by the design professional. Specifier notes (shaded) and bracketed options [ ]✕ must be edited or deleted before issue. Highlighted items [...]✕ are manufacturer data to be confirmed by Nova USA Wood Products before this document is published.
SPECIFIER NOTEThis section is based on products of Nova USA Wood Products, 3821 24th Avenue, Forest Grove, OR 97116. Tel: (503) 419-6407. Email: sales@novausawood.com. Web: www.novausawood.com. BIM files for rainscreen, decking and clip profiles, profile drawings, installation guides and warranties are at www.novausawood.com/downloads. Technical support, samples and AIA continuing education presentations are available from the manufacturer.
SPECIFIER NOTEThis section covers interior solid-wood board paneling on walls and ceilings, including wainscoting. Interior wall and ceiling finishes are limited by flame-spread class according to occupancy and location under IBC Section 803. Confirm the class required for each location and retain only species with qualifying test data.

PART 1 - GENERAL

1.1SUMMARY
A.Section Includes:
1.Solid wood board paneling on walls.
2.Solid wood board ceilings.
3.Wainscoting and cap trim.
B.Related Requirements:
1.Section 06 10 00 "Rough Carpentry" for furring and blocking.
2.Section 09 93 00 "Staining and Transparent Finishing."
1.2REFERENCES
A.ASTM E84 - Surface Burning Characteristics of Building Materials.
B.International Building Code Section 803 - Wall and Ceiling Finishes.
C.WCLIB Standard No. 17 - Grading Rules for West Coast Lumber.
D.AWPA U1 - Use Category System: User Specification for Treated Wood.
E.AWPA T1 - Processing and Treatment Standard.
1.3PERFORMANCE REQUIREMENTS
A.Interior Finish Classification: Paneling and ceilings shall have flame-spread and smoke-developed indexes per ASTM E84 meeting [Class A (FSI 0-25)] [Class B (FSI 26-75)] [Class C (FSI 76-200)], smoke-developed index 450 maximum, as required by IBC Section 803 for the occupancy and location.
B.[Ignition-Resistant Treatment: Where a rated finish is required, provide [Inari] [Ambara] factory pressure-treated with an exterior-type fire-retardant treatment complying with AWPA U1 Use Category UCFB (exterior, above ground) and treated in accordance with AWPA T1, kiln dried after treatment (KDAT) to 15 percent maximum moisture content, meeting: IBC Section 2303.2 fire-retardant-treated wood; ignition-resistant material per IWUIC Section 503.2 and CBC Chapter 7A; ASTM E84 / UL 723 flame-spread index 25 or less with the test extended to 30 minutes per ASTM E2768 and flame front not progressing more than 10.5 feet (3.2 m) beyond the burner centerline; no increase in classification after accelerated weathering per ASTM D2898. Evaluation: current ICC-ES or UL evaluation report and CSFM BML listing of the treater used [report and listing numbers by treater]✕. Each piece shall bear the mark of the independent inspection agency indicating the extended 30-minute ASTM E84 test. Supply a certificate of treatment with each shipment identifying the treater, evaluation report and listing.]✕
1.4ACTION SUBMITTALS
A.Product Data: For each product, include species, grade, profile, moisture content, physical and mechanical properties, and finish.
B.Shop Drawings: Show layout, profiles, attachment, clip and fastener spacing, joints, terminations, penetrations, and transitions to adjacent construction.
C.Samples for Initial Selection: Manufacturer's standard samples showing range of color and grain for each species and factory finish specified.
D.Samples for Verification: Two samples of each species, profile and finish, not less than 12 inches (305 mm) long, showing expected range of color and grain.
1.5INFORMATIONAL SUBMITTALS
A.Product Test Reports: From a qualified independent testing agency, indicating compliance with the performance requirements in Part 2, including fire-test-response characteristics.
B.Manufacturer's Installation Instructions: Current editions of the manufacturer's published installation guides referenced in Part 3.
C.Legality Documentation: Manufacturer's declaration that wood products are legally harvested and imported in compliance with the U.S. Lacey Act, maintained under the manufacturer's written Lacey Act Compliance Program (supplier due-diligence questionnaire covering species, country and region of harvest, harvest permits and CITES status; PPQ 505 import declarations; seven-year record retention). Documentation available on request.
D.Sustainability Documentation: Manufacturer's LEED v4/v4.1 alignment statement (www.novausawood.com/PDFs/Nova-LEEDS-Alignment.pdf).
SPECIFIER NOTENova's source mills hold FSC or PEFC certification, but Nova does not currently hold its own chain-of-custody certificate, so products are not sold with a certified claim and do not contribute to LEED MR sourcing credits as supplied. Where certified wood is required, contact Nova before bid to arrange certified supply.
E.Acclimation Record: Dated moisture-meter readings, with photographs, of boards selected at random throughout each delivery, and the site equilibrium moisture content, submitted before installation begins.
1.6CLOSEOUT SUBMITTALS
A.Maintenance Data: Manufacturer's published maintenance guide for each product and finish.
B.Warranty: Executed manufacturer's warranty as specified.
1.7QUALITY ASSURANCE
A.Manufacturer Qualifications: A firm with not less than 10 years of experience supplying products of the type specified.
B.Installer Qualifications: A firm with not less than one year of experience installing interior wood paneling in solid wood (not composite or PVC) of similar scope, familiar with the manufacturer's installation guides referenced in Part 3.
C.Mockups: Build mockup not less than 4 feet (1.2 m) by 8 feet (2.4 m) on wall and ceiling, with selected finish to verify selections, workmanship, attachment and finish.
1.Approval of mockup does not constitute approval of deviations from the Contract Documents.
2.Approved mockup may become part of the completed Work if undisturbed at Substantial Completion.
D.Preinstallation Conference: Conduct at Project site with Installer and manufacturer's representative. Review storage, acclimation and the Acclimation Record.
1.8DELIVERY, STORAGE, AND HANDLING
A.Deliver materials with packing list identifying species, grade, profile, quantity and lengths, and accessories.
B.Store materials flat, off the ground on level supports not less than 4 inches (100 mm) above grade, under breathable cover that sheds water while allowing air circulation. Do not wrap tightly in polyethylene.
C.Acclimate materials at Project site in accordance with manufacturer's "Acclimating Siding and Decking" guide (https://www.novausawood.com/PDFs/acclimating-siding-decking.pdf) until average moisture content is within 2 percent of the site equilibrium moisture content (EMC). Do not base acclimation on time alone.
1.Restack with stickers not less than 3/4 inch (19 mm) thick spaced not more than 12 inches (305 mm) apart; keep stacks out of direct sun and water, with covers held off the stack.
2.Verify with a moisture meter on boards selected at random throughout the stack; record, date and photograph readings and submit to the Architect as the Acclimation Record before installation begins.
D.Deliver interior paneling only after building is enclosed and HVAC is operating. Acclimate in the installation space until moisture content is within 2 percent of the interior equilibrium moisture content, and for not less than 72 hours.
1.9FIELD CONDITIONS
A.Maintain temperature and relative humidity at levels expected during occupancy for not less than 7 days before and during installation.

PART 2 - PRODUCTS

2.1MANUFACTURERS
SPECIFIER NOTEChoose ONE of the two options below. Option 1 (basis of design) is recommended for most public and private work: it names Nova while allowing the contractor to propose an equal under Division 01. Use Option 2 (proprietary) only where the Owner permits a sole-source specification.
A.Basis-of-Design Product: Subject to compliance with requirements, provide [Ambara] [Inari] [Korina] [Batu] [Douglas Fir clear] paneling by Nova USA Wood Products, Forest Grove, Oregon; www.novausawood.com.
1.Comparable Products: Products of other manufacturers will be considered when they meet every performance requirement of this Section, documented by test reports from independent laboratories, and are approved by the Architect in accordance with Section 01 60 00 - Product Requirements.
2.Substitutions: Not permitted.
B.Source Limitations: Obtain each product type, including clips, fasteners, end sealer and factory finish, from a single source through one manufacturer.
2.2SPECIES
SPECIFIER NOTEUntreated Ambara and Inari are not rated Class A or B and are limited to locations where IBC Section 803 permits unrated or Class C interior finish, as accepted by the authority having jurisdiction. Where Class A or B is required, retain the ignition-resistant treatment paragraph or select Batu (Class A).
Species (Basis of Design)Botanical name / gradeDensityFSI / SDIClass
Thermally modified Ayous (Nova Ambara)Triplochiton scleroxylon; A & Btr Clear320 kg/m3Not testedNot A/B untreated; ignition-resistant extended Class A when treated
Thermally modified Nordic spruce (Nova Inari)Picea abies; Select Knotty (WCLIB 111-e, f)440 kg/m3Not testedNot A/B untreated; ignition-resistant extended Class A when treated
Thermally modified hardwood (Nova Korina)Terminalia superba; Standard & Btr600 kg/m3Not testedNot tested
Batu / Red Balau (Nova Batu)Shorea guiso; Standard & Btr (FAS equivalent)850 kg/m325 / 65 (1-inch board)A
Douglas fir clear (Nova Douglas Fir)Pseudotsuga menziesii; VGX(R) 85/15 Clear, fine grain510 kg/m3Not testedNot tested
A.Moisture Content at Shipment: Tropical hardwood and Douglas fir pattern stock kiln dried to 10 to 12 percent; thermally modified wood 6 to 8 percent.
SPECIFIER NOTEPattern stock at 10 to 12 percent will shrink in heated or air-conditioned interiors. Retain the acclimation requirements in Part 1 and Part 3 and verify moisture content within 2 percent of interior EMC before installation.
2.3PANELING BOARDS
A.Profile: Per Nova Standard Profiles (www.novausawood.com/standard-profiles; downloadable SVG drawings):
1.[1 x 4 Nickel Gap / Edge V Combination T&G, 3/4 inch (19 mm) thick, 3 inch (76 mm) face.]✕
2.[1 x 6 [Nickel Gap] [Edge V] [Combination] T&G, flat back, 3/4 inch (19 mm) thick, 5 inch (127 mm) face.]✕
3.[1 x 8 [Nickel Gap] [Edge V] T&G, flat back, 3/4 inch (19 mm) thick, 7 inch (178 mm) face.]✕
4.[1 x 8 T&G Fluted Paneling, 13/16 inch (21 mm) thick, 6.585 inch (167 mm) coverage.]✕
5.[6/4 x 8 T&G Quad Shadow Paneling, 1-1/4 inch (32 mm) thick, 6.585 inch (167 mm) coverage.]✕
6.[5/8 x 4 or 5/8 x 6 Combination Ceiling, 9/16 inch (14 mm) thick (ceilings).]✕
7.Profile availability by species: Ambara 1x2 through 2x12; Inari and Korina 1x2 through 2x8 (nominal widths to 8 inches); Batu 1x2 through 2x12; Douglas fir clears 1x2 through 2x12.
B.Dimensional Tolerance: Net dimensions plus 0 inch, minus 1/16 inch (1.5 mm) at time of manufacture; boards within a production batch plus or minus 1/64 inch (0.4 mm). Dimensions change with moisture content during acclimation.
C.Size: Nominal [1 x 4] [1 x 6] [1 x 8], dressed to American Softwood Lumber Standard (PS 20) sizes or standard industry practice: 1x nominal = 3/4 inch (19 mm) net; 5/4 nominal = 1 inch (25 mm) net; 2x nominal = 1-1/2 inches (38 mm) net. Net widths: 2 = 1-1/2 in.; 3 = 2-1/2 in.; 4 = 3-1/2 in.; 6 = 5-1/2 in.; 8 = 7-1/4 in.; 10 = 9-1/4 in.; 12 = 11-1/4 in. Lengths 8 to 20 feet (2.4 to 6.1 m), odd and even lengths.
D.Wainscot: Height as indicated, with [matching species cap and base] [cap as detailed].
E.Orientation: [Horizontal] [Vertical] [Diagonal], as indicated.
2.4FASTENERS
A.Fasteners: Concealed blind-nailing or stainless steel finish nails through tongue; adhesive where recommended by manufacturer. [Nova ExoClad QuickClip for clip-milled boards.]✕
2.5FINISH
A.Finish: [Unfinished] [Clear finish] [Nova ExoShield Clear, per Section 09 93 00].
SPECIFIER NOTEExoShield VOC content is less than 150 g/L. Where the project requires low-emitting interior products (for example LEED v4.1 EQ Low-Emitting Materials or CDPH Standard Method), confirm compliance or specify a compliant interior clear finish.

PART 3 - EXECUTION

3.1EXAMINATION
A.Verify furring and blocking are complete, flat within 1/8 inch in 8 feet (3 mm in 2.4 m), and that wet work is complete and dry.
SPECIFIER NOTEInadequate acclimation is the most common cause of field problems with solid wood: open joints, cupping and buckling. Retain the acclimation hold point below.
B.Acclimation: Do not begin installation until the Architect has received an Acclimation Record showing average moisture content within 2 percent of the site equilibrium moisture content. Material installed without an Acclimation Record will be rejected.
3.2INSTALLATION
A.Install in accordance with standard practice for solid wood board paneling (as for cedar and Douglas fir tongue-and-groove): blind-nail through the tongue at each furring member or stud with stainless steel finish nails; face-nail only the first and last boards; leave the tongue joint snug, not tight, to allow seasonal movement.
B.Install with tight joints, consistent reveals, and joints staggered and located over supports. Leave expansion space at perimeters concealed by trim.
C.Scribe to adjacent surfaces. Coordinate cutouts for lighting, diffusers and devices.
3.3CLEANING AND PROTECTION
A.Protect installed paneling from damage and soiling. Replace damaged boards.

END OF SECTION