Section 06 15 00 Modified Wood Decking
Nova guide specification, CSI SectionFormat. Answer the project questions and the spec rewrites itself: options resolve, unused species drop out, and fire, coastal and warranty requirements follow your choices. Click any [bracket] to choose by hand.
SECTION 06 15 00
MODIFIED WOOD DECKING
SPECIFIER NOTEThis guide specification is written in CSI SectionFormat and PageFormat for editing by the design professional. Specifier notes (shaded) and bracketed options [ ]✕ must be edited or deleted before issue. Highlighted items [...]✕ are manufacturer data to be confirmed by Nova USA Wood Products before this document is published.
SPECIFIER NOTEThis section is based on products of Nova USA Wood Products, 3821 24th Avenue, Forest Grove, OR 97116. Tel: (503) 419-6407. Email: sales@novausawood.com. Web: www.novausawood.com. BIM files for rainscreen, decking and clip profiles, profile drawings, installation guides and warranties are at www.novausawood.com/downloads. Technical support, samples and AIA continuing education presentations are available from the manufacturer.
SPECIFIER NOTEThis section covers exterior modified wood deck boards (thermally modified Inari, Korina and DuraTau, and extractive-free Melywood) with concealed clip attachment. For tropical hardwood decking and deck tiles, use the Nova Tropical Hardwood Decking section. Modified wood is not "naturally durable wood" or "preservative-treated wood" as defined in the IBC; use it for deck surface boards, not for structural framing in contact with the ground.
PART 1 - GENERAL
1.1SUMMARY
A.Section Includes:
1.Modified wood deck boards and stair treads.
2.[Modified wood dimensional lumber and posts for rails and benches.]✕
3.Fasteners[ and concealed deck clips]✕.
4.End-grain sealer and [factory] [field] finish.
B.Related Requirements:
1.Section 06 10 00 "Rough Carpentry" for deck framing.
2.Section 06 15 00 "Tropical Hardwood Decking and Deck Tiles."
3.Section 09 93 00 "Staining and Transparent Finishing."
1.2REFERENCES
A.ASTM D143 - Small Clear Specimens of Timber.
B.ASTM E84 - Surface Burning Characteristics of Building Materials.
C.California State Fire Marshal SFM Standard 12-7A-4 - Decking.
D.ASTM D1413 - Wood Preservatives by Laboratory Soil-Block Cultures; AWPA E10.
E.EN 350 - Durability of Wood and Wood-Based Products; EN 335 - Use Classes.
F.ThermoWood Association - ThermoWood Handbook, product class Thermo-D.
1.3PERFORMANCE REQUIREMENTS
A.Structural: Deck boards shall support a uniform live load of [100 psf (4.8 kPa), residential] [200 psf (9.6 kPa), commercial] on joists spaced not more than 16 inches (406 mm) o.c. perpendicular or 12 inches (305 mm) o.c. diagonal.
B.Fire-Test-Response Characteristics:
1.Surface-Burning Characteristics: ASTM E84 values for each species listed in Part 2.
2.[Wildland-Urban Interface: Decking shall comply with SFM Standard 12-7A-4.]✕
SPECIFIER NOTEInari, Korina, DuraTau and Melywood have not been tested to SFM 12-7A-4. In WUI areas, use tested tropical hardwood decking or obtain approval from the authority having jurisdiction.
1.4ACTION SUBMITTALS
A.Product Data: For each product, include species, grade, profile, moisture content, physical and mechanical properties, and finish.
B.Shop Drawings: Show layout, profiles, attachment, clip and fastener spacing, joints, terminations, penetrations, and transitions to adjacent construction.
C.Samples for Initial Selection: Manufacturer's standard samples showing range of color and grain for each species and factory finish specified.
D.Samples for Verification: Two samples of each species, profile and finish, not less than 12 inches (305 mm) long, showing expected range of color and grain.
1.5INFORMATIONAL SUBMITTALS
A.Product Test Reports: From a qualified independent testing agency, indicating compliance with the performance requirements in Part 2, including fire-test-response characteristics.
B.Manufacturer's Installation Instructions: Current editions of the manufacturer's published installation guides referenced in Part 3.
C.Legality Documentation: Manufacturer's declaration that wood products are legally harvested and imported in compliance with the U.S. Lacey Act, maintained under the manufacturer's written Lacey Act Compliance Program (supplier due-diligence questionnaire covering species, country and region of harvest, harvest permits and CITES status; PPQ 505 import declarations; seven-year record retention). Documentation available on request.
D.Sustainability Documentation: Manufacturer's LEED v4/v4.1 alignment statement (www.novausawood.com/PDFs/Nova-LEEDS-Alignment.pdf).
SPECIFIER NOTENova's source mills hold FSC or PEFC certification, but Nova does not currently hold its own chain-of-custody certificate, so products are not sold with a certified claim and do not contribute to LEED MR sourcing credits as supplied. Where certified wood is required, contact Nova before bid to arrange certified supply.
E.Acclimation Record: Dated moisture-meter readings, with photographs, of boards selected at random throughout each delivery, and the site equilibrium moisture content, submitted before installation begins.
1.6CLOSEOUT SUBMITTALS
A.Maintenance Data: Manufacturer's published maintenance guide for each product and finish.
B.Warranty: Executed manufacturer's warranty as specified.
1.7QUALITY ASSURANCE
A.Manufacturer Qualifications: A firm with not less than 10 years of experience supplying products of the type specified.
B.Installer Qualifications: A firm with not less than one year of experience installing wood decking in solid wood (not composite or PVC) of similar scope, familiar with the manufacturer's installation guides referenced in Part 3.
C.Mockups: Build mockup not less than 8 feet (2.4 m) by 8 feet (2.4 m), including a deck edge, a stair tread, and the selected finish to verify selections, workmanship, attachment and finish.
1.Approval of mockup does not constitute approval of deviations from the Contract Documents.
2.Approved mockup may become part of the completed Work if undisturbed at Substantial Completion.
D.Preinstallation Conference: Conduct at Project site with Installer and manufacturer's representative. Review storage, acclimation and the Acclimation Record.
1.8DELIVERY, STORAGE, AND HANDLING
A.Deliver materials with packing list identifying species, grade, profile, quantity and lengths, and accessories.
B.Store materials flat, off the ground on level supports not less than 4 inches (100 mm) above grade, under breathable cover that sheds water while allowing air circulation. Do not wrap tightly in polyethylene.
C.Acclimate materials at Project site in accordance with manufacturer's "Acclimating Siding and Decking" guide (https://www.novausawood.com/PDFs/acclimating-siding-decking.pdf) until average moisture content is within 2 percent of the site equilibrium moisture content (EMC). Do not base acclimation on time alone.
1.Restack with stickers not less than 3/4 inch (19 mm) thick spaced not more than 12 inches (305 mm) apart; keep stacks out of direct sun and water, with covers held off the stack.
2.Verify with a moisture meter on boards selected at random throughout the stack; record, date and photograph readings and submit to the Architect as the Acclimation Record before installation begins.
1.9WARRANTY
SPECIFIER NOTEManufacturer's warranties apply to residential and commercial projects and cover material only; labor is excluded. Confirm terms against the current published warranty documents before issue.
A.Deck Boards (Inari, Korina, DuraTau, Melywood): Manufacturer's limited warranty that the wood will not suffer structural damage from rot and decay for 25 years from date of purchase. Remedy at manufacturer's option: replacement boards, repair, or cash compensation prorated by years in service; labor excluded. Register within 90 days after installation per manufacturer's procedure (www.novausawood.com/warranty-registration), with dealer receipt and project photo; include the registration confirmation with closeout submittals. Reference: Nova Thermally Modified Wood Warranty (https://www.novausawood.com/PDFs/nova-thermal-modified-warranty-2026.pdf).
B.[Clips: Manufacturer's limited lifetime warranty for ExoDek QuickClip, as defined in the manufacturer's published warranty. Register the warranty in the Owner's name within 90 days of purchase at www.novausawood.com/warranty-registration and include the registration receipt with closeout submittals. Reference: ExoDek QuickClip Warranty (https://www.novausawood.com/PDFs/nova-decking-clips-warranty.pdf).]✕
PART 2 - PRODUCTS
2.1MANUFACTURERS
SPECIFIER NOTEChoose ONE of the two options below. Option 1 (basis of design) is recommended for most public and private work: it names Nova while allowing the contractor to propose an equal under Division 01. Use Option 2 (proprietary) only where the Owner permits a sole-source specification.
A.Basis-of-Design Product: Subject to compliance with requirements, provide [Inari] [Korina] [DuraTau] [Melywood] modified wood decking[ with Nova ExoDek QuickClip concealed clips]✕ by Nova USA Wood Products, Forest Grove, Oregon; www.novausawood.com.
1.Comparable Products: Products of other manufacturers will be considered when they meet every performance requirement of this Section, documented by test reports from independent laboratories, and are approved by the Architect in accordance with Section 01 60 00 - Product Requirements.
2.Substitutions: Not permitted.
B.Source Limitations: Obtain each product type, including [clips, ]✕fasteners, end sealer and factory finish, from a single source through one manufacturer.
2.2DECK BOARD SPECIES
A.Thermally Modified Nordic Spruce (Basis of Design: Nova Inari):
1.Species: Picea abies, thermally modified to ThermoWood Association product class Thermo-D (212 deg C plus or minus 3 deg C), using heat and steam only.
2.Durability: Durability Class 2 (durable) per EN 350, suitable for Use Class 3 (outdoors, exposed to weather) per EN 335.
3.Density 440 kg/m3; MOR 9,500 psi; MOE 1,500,000 psi; Janka 380 lbf; shrinkage less than 2.0 percent.
4.Grade: Select Knotty, equivalent to WCLIB No. 17, paragraph 111-e, f.
5.Fire: Untreated: not tunnel-tested; not tested to SFM 12-7A-4.
B.Thermally Modified Hardwood (Basis of Design: Nova Korina):
1.Species: Terminalia superba (also sold as Frake or Limba), thermally modified by a proprietary closed-system process using heat and steam only. No chemicals, preservatives or resins.
2.Decay Resistance: Durability Class 2 (durable) per EN 350, as reported by the producer.
3.Dimensional Stability: Swelling and shrinkage less than 2 percent.
4.Density 600 kg/m3; MOR 12,510 psi; MOE 1,520,000 psi; Janka 670 lbf (ASTM D143, 12 percent MC).
5.Grade: Standard and Better.
6.Fire: Untreated: not tunnel-tested; not tested to SFM 12-7A-4.
C.Thermally Modified Tauari (Basis of Design: Nova DuraTau):
1.Species: Couratari stellata (Tauari; also traded as Tauari Escuro, Tauari Amarelo, Imbirema, Estopeiro, Capa de Tabaco and Brazilian Oak), thermally modified by a proprietary closed-system process using heat and steam only. No chemicals, preservatives or resins.
2.Decay Resistance: Durability Class 2 (durable) per EN 350.
3.Dimensional Stability: Radial and tangential shrinkage less than 2.0 percent.
4.Density 510 kg/m3; MOR 12,100 psi; MOE 1,800,000 psi; Janka 1,330 lbf.
5.Grade: First Clear.
6.Fire: Untreated: not tunnel-tested; not tested to SFM 12-7A-4.
D.Tannin-Free Merbau (Basis of Design: Melywood(R)):
1.Species: Merbau, Intsia bijuga, from Indonesia, modified by the producer's proprietary injection process that neutralizes the tannins in the wood fiber to prevent tannin bleed and staining.
2.Decay Resistance: Durability Class 1 to 2 (very durable to durable) against fungi per EN 350; termites Class D (durable); suitable for Use Class 4 (in contact with ground or fresh water) per EN 335. Not recommended for submerged marine use.
3.Dimensional Stability: Swelling and shrinkage less than 2 percent.
4.Density 750 kg/m3 (producer data); MOR 16,800 psi; MOE 2,230,000 psi; Janka (side hardness) 1,500 lbf at 15 percent moisture content (USDA FPL Wood Handbook, FPL-GTR-190, Table 5-5b). Kiln dried to 13 percent plus or minus 2 percent before modification.
5.Grade: FAS (equivalent to Standard and Better), mixed grain.
6.Fire: Untreated: not tunnel-tested; not tested to SFM 12-7A-4.
2.3DECK BOARDS
A.Sizes: [1 x 4] [1 x 6] [1 x 8] [5/4 x 4] [5/4 x 6] [5/4 x 8] nominal (availability: Inari and Korina, 1x and 5/4, nominal widths to 8 inches; DuraTau 1 x 4, 1 x 6, 5/4 x 4 and 5/4 x 6; Melywood 5/4 x 6 only), dressed to American Softwood Lumber Standard (PS 20) sizes or standard industry practice: 1x nominal = 3/4 inch (19 mm) net; 5/4 nominal = 1 inch (25 mm) net; 2x nominal = 1-1/2 inches (38 mm) net. Net widths: 2 = 1-1/2 in.; 3 = 2-1/2 in.; 4 = 3-1/2 in.; 6 = 5-1/2 in.; 8 = 7-1/4 in.; 10 = 9-1/4 in.; 12 = 11-1/4 in.
B.Profile: Surfaced four sides, eased edges, [grooved both edges for concealed clips; groove 3/16 inch (5 mm) high centered on board thickness, lower edge 13/32 inch (10 mm) above bottom face, depth 1/2 inch (13 mm)] [smooth edges (S4S E4E) for face screwing]. Profile drawings: Nova Standard Profiles (www.novausawood.com/standard-profiles; downloadable SVG drawings).
C.Lengths: [8 to 20 feet (2.4 to 6.1 m), even lengths; Inari in metric lengths 2.7 to 5.7 m (approximately 8 feet 10 inches to 18 feet 8 inches) in 0.3 m increments] [Specified lengths, cut to length by manufacturer: ].
D.Moisture Content at Shipment: Thermally modified (Inari, Korina, DuraTau) 6 to 8 percent; Melywood 12 to 14 percent. Acclimate to project-site equilibrium moisture content before installation, particularly in dry climates.
E.Dimensional Tolerance: Net dimensions plus 0 inch, minus 1/16 inch (1.5 mm) at time of manufacture; boards within a production batch plus or minus 1/64 inch (0.4 mm). Dimensions change with moisture content during acclimation.
F.[Dimensional Lumber (Korina): S4S, eased edges; 2 x 2 through 2 x 8 nominal.]✕
2.4ATTACHMENT
A.[Concealed Clips: Nova ExoDek QuickClip, glass-fiber-reinforced nylon, screwed to joists; holds boards above joists for airflow and sets a 1/4-inch (6 mm) gap between boards.]✕
B.[Clip Screws: 1-5/8-inch (41 mm) #7 Type 305 stainless steel T-15 Torx-drive screws, with driver bits, supplied with the clips. Within 20 miles (32 km) of salt water, do not use the supplied screws; furnish separate Type 316 stainless steel screws of the same size.]✕
C.Face Fasteners ([all boards, face-screwed installations] [stair nosings and board ends where required]): [Type 304] [Type 316] stainless steel screws, predrilled and countersunk. Use Type 316 within 20 miles (32 km) of salt water.
D.End-Grain Sealer: Nova ExoWax end sealer, applied to all field-cut ends and any field-drilled holes.
2.5FINISH
SPECIFIER NOTEManufacturer's warranty for clip-attached (hidden-fastener) decking requires pre-grooved boards and an approved oil-based exterior finish on all sides. Face-screwed installations may be left unfinished.
A.Finish: [Unfinished, allowed to weather (face-screwed installations only)] [Nova ExoShield on all four sides, color: , [factory applied] [field applied per Section 09 93 00]] [Other finish selected by Architect: , factory applied by manufacturer].
SPECIFIER NOTENova factory-applies ExoShield and, on request, other penetrating finishes (for example Cutek, Renner, Sansin, Penofin, Messmer's, Seal-Once, Ready Seal). Nova states performance only for ExoShield: recoat siding at 3 to 5 years and decking at 1 year. Maintenance intervals for other finishes vary by product, from 6 months to 1 year on decking.
PART 3 - EXECUTION
3.1EXAMINATION
A.Verify framing is level and joists are spaced not more than 16 inches (406 mm) o.c. perpendicular or 12 inches (305 mm) o.c. diagonal.
B.Verify conditions required by manufacturer's warranty: clearance from deck surface to grade not less than 36 inches (914 mm) for 6-inch-wide boards and 16 inches (406 mm) for 4-inch-wide boards; not less than 50 percent unrestricted open area on at least three sides; exposed ground below deck covered with vapor barrier and sloped not less than 1:12 away from structure.
SPECIFIER NOTEInadequate acclimation is the most common cause of field problems with solid wood: open joints, cupping and buckling. Retain the acclimation hold point below.
C.Acclimation: Do not begin installation until the Architect has received an Acclimation Record showing average moisture content within 2 percent of the site equilibrium moisture content. Material installed without an Acclimation Record will be rejected.
3.2INSTALLATION
A.Install in accordance with Nova's ["ExoDek QuickClip Installation Guide" (https://www.novausawood.com/PDFs/ExoDek-QuickClip-Installation-Guide.pdf) and ]✕"Decking Installation Guide" (https://www.novausawood.com/PDFs/Decking-Installation-Guide.pdf), current edition at time of bid (guides are revised quarterly).
B.Install boards perpendicular to joists with joints over joists; stagger end joints.
C.Seal all field-cut ends with ExoWax immediately after cutting.
D.Maintain end and edge gaps recommended by the manufacturer.
3.3CLEANING AND PROTECTION
A.Protect decking from construction traffic and staining. Replace damaged boards.
END OF SECTION