Section 06 20 13 Exterior Finish Carpentry
Nova guide specification, CSI SectionFormat. Answer the project questions and the spec rewrites itself: options resolve, unused species drop out, and fire, coastal and warranty requirements follow your choices. Click any [bracket] to choose by hand.
SECTION 06 20 13
EXTERIOR FINISH CARPENTRY
SPECIFIER NOTEThis guide specification is written in CSI SectionFormat and PageFormat for editing by the design professional. Specifier notes (shaded) and bracketed options [ ]✕ must be edited or deleted before issue. Highlighted items [...]✕ are manufacturer data to be confirmed by Nova USA Wood Products before this document is published.
SPECIFIER NOTEThis section is based on products of Nova USA Wood Products, 3821 24th Avenue, Forest Grove, OR 97116. Tel: (503) 419-6407. Email: sales@novausawood.com. Web: www.novausawood.com. BIM files for rainscreen, decking and clip profiles, profile drawings, installation guides and warranties are at www.novausawood.com/downloads. Technical support, samples and AIA continuing education presentations are available from the manufacturer.
SPECIFIER NOTEThis section covers exterior wood trim, fascia, soffits, porch ceilings and board applications. For rainscreen siding use Section 07 46 23; for interior paneling use Section 06 42 00.
PART 1 - GENERAL
1.1SUMMARY
A.Section Includes:
1.Exterior trim, fascia and rake boards.
2.Soffits and porch ceilings.
3.Exterior boards for screens, fences and site elements.
B.Related Requirements:
1.Section 06 10 00 "Rough Carpentry."
2.Section 07 46 23 "Wood Siding."
3.Section 09 93 00 "Staining and Transparent Finishing."
1.2REFERENCES
A.ASTM E84 - Surface Burning Characteristics of Building Materials.
B.California State Fire Marshal SFM Standards 12-7A-2 (Eaves) and 12-7A-3 (Horizontal Projection Underside).
C.WCLIB Standard No. 17 - Grading Rules for West Coast Lumber.
D.AWPA U1 - Use Category System: User Specification for Treated Wood.
E.AWPA T1 - Processing and Treatment Standard.
1.3PERFORMANCE REQUIREMENTS
A.Fire-Test-Response Characteristics: ASTM E84 values for each species listed in Part 2.
B.[Wildland-Urban Interface: Eaves and soffits shall comply with [SFM 12-7A-2] [SFM 12-7A-3] or be installed in a tested assembly.]✕
C.[Ignition-Resistant Treatment: Provide [Inari] [Ambara] trim, fascia and soffit material factory pressure-treated with an exterior-type fire-retardant treatment complying with AWPA U1 Use Category UCFB (exterior, above ground) and treated in accordance with AWPA T1, kiln dried after treatment (KDAT) to 15 percent maximum moisture content, meeting: IBC Section 2303.2 fire-retardant-treated wood; ignition-resistant material per IWUIC Section 503.2 and CBC Chapter 7A; ASTM E84 / UL 723 flame-spread index 25 or less with the test extended to 30 minutes per ASTM E2768 and flame front not progressing more than 10.5 feet (3.2 m) beyond the burner centerline; no increase in classification after accelerated weathering per ASTM D2898. Evaluation: current ICC-ES or UL evaluation report and CSFM BML listing of the treater used [report and listing numbers by treater]✕. Each piece shall bear the mark of the independent inspection agency indicating the extended 30-minute ASTM E84 test. Supply a certificate of treatment with each shipment identifying the treater, evaluation report and listing.]✕
SPECIFIER NOTEIgnition-resistant material is one of the code paths for eaves and soffits in Wildland-Urban Interface areas; confirm acceptance with the authority having jurisdiction.
SPECIFIER NOTENova's SFM 12-7A-1 listing covers Ambara exterior wall siding only. No eave or soffit testing (SFM 12-7A-2 or 12-7A-3) is documented. Confirm before retaining the WUI paragraph.
1.4ACTION SUBMITTALS
A.Product Data: For each product, include species, grade, profile, moisture content, physical and mechanical properties, and finish.
B.Shop Drawings: Show layout, profiles, attachment, clip and fastener spacing, joints, terminations, penetrations, and transitions to adjacent construction.
C.Samples for Initial Selection: Manufacturer's standard samples showing range of color and grain for each species and factory finish specified.
D.Samples for Verification: Two samples of each species, profile and finish, not less than 12 inches (305 mm) long, showing expected range of color and grain.
1.5INFORMATIONAL SUBMITTALS
A.Product Test Reports: From a qualified independent testing agency, indicating compliance with the performance requirements in Part 2, including fire-test-response characteristics.
B.Manufacturer's Installation Instructions: Current editions of the manufacturer's published installation guides referenced in Part 3.
C.Legality Documentation: Manufacturer's declaration that wood products are legally harvested and imported in compliance with the U.S. Lacey Act, maintained under the manufacturer's written Lacey Act Compliance Program (supplier due-diligence questionnaire covering species, country and region of harvest, harvest permits and CITES status; PPQ 505 import declarations; seven-year record retention). Documentation available on request.
D.Sustainability Documentation: Manufacturer's LEED v4/v4.1 alignment statement (www.novausawood.com/PDFs/Nova-LEEDS-Alignment.pdf).
SPECIFIER NOTENova's source mills hold FSC or PEFC certification, but Nova does not currently hold its own chain-of-custody certificate, so products are not sold with a certified claim and do not contribute to LEED MR sourcing credits as supplied. Where certified wood is required, contact Nova before bid to arrange certified supply.
E.Acclimation Record: Dated moisture-meter readings, with photographs, of boards selected at random throughout each delivery, and the site equilibrium moisture content, submitted before installation begins.
1.6CLOSEOUT SUBMITTALS
A.Maintenance Data: Manufacturer's published maintenance guide for each product and finish.
B.Warranty: Executed manufacturer's warranty as specified.
1.7QUALITY ASSURANCE
A.Manufacturer Qualifications: A firm with not less than 10 years of experience supplying products of the type specified.
B.Installer Qualifications: A firm with not less than one year of experience installing exterior finish carpentry in solid wood (not composite or PVC) of similar scope, familiar with the manufacturer's installation guides referenced in Part 3.
C.Mockups: Build mockup of a typical eave and soffit corner, not less than 8 feet (2.4 m) long, with selected finish to verify selections, workmanship, attachment and finish.
1.Approval of mockup does not constitute approval of deviations from the Contract Documents.
2.Approved mockup may become part of the completed Work if undisturbed at Substantial Completion.
D.Preinstallation Conference: Conduct at Project site with Installer and manufacturer's representative. Review storage, acclimation and the Acclimation Record.
1.8DELIVERY, STORAGE, AND HANDLING
A.Deliver materials with packing list identifying species, grade, profile, quantity and lengths, and accessories.
B.Store materials flat, off the ground on level supports not less than 4 inches (100 mm) above grade, under breathable cover that sheds water while allowing air circulation. Do not wrap tightly in polyethylene.
C.Acclimate materials at Project site in accordance with manufacturer's "Acclimating Siding and Decking" guide (https://www.novausawood.com/PDFs/acclimating-siding-decking.pdf) until average moisture content is within 2 percent of the site equilibrium moisture content (EMC). Do not base acclimation on time alone.
1.Restack with stickers not less than 3/4 inch (19 mm) thick spaced not more than 12 inches (305 mm) apart; keep stacks out of direct sun and water, with covers held off the stack.
2.Verify with a moisture meter on boards selected at random throughout the stack; record, date and photograph readings and submit to the Architect as the Acclimation Record before installation begins.
D.Tannin Bleed (Batu): Batu contains water-soluble extractives (tannins) that bleed when wet and can stain concrete, masonry, stone and light-colored adjacent finishes. Store away from these surfaces with the ground beneath covered, protect adjacent surfaces from runoff during construction, and clean any staining in accordance with the manufacturer's maintenance guide. Bleeding diminishes after the first several rains.
1.9WARRANTY
SPECIFIER NOTEManufacturer's warranties apply to residential and commercial projects and cover material only; labor is excluded. Confirm terms against the current published warranty documents before issue.
A.Thermally Modified Wood and Melywood: Manufacturer's limited warranty that the wood will not suffer structural damage from rot and decay for 25 years from date of purchase. Remedy at manufacturer's option: replacement boards, repair, or cash compensation prorated by years in service; labor excluded. Register within 90 days after installation per manufacturer's procedure (www.novausawood.com/warranty-registration), with dealer receipt and project photo; include the registration confirmation with closeout submittals. Reference: Nova Thermally Modified Wood Warranty (https://www.novausawood.com/PDFs/nova-thermal-modified-warranty-2026.pdf).
B.Tropical Hardwood: Manufacturer's limited warranty that the wood will not suffer structural damage from rot, decay or termites for 25 years from date of purchase. Remedy at manufacturer's option: replacement boards, repair, or cash compensation prorated by years in service; labor excluded. Register within 90 days after installation per manufacturer's procedure (www.novausawood.com/warranty-registration), with dealer receipt and project photo; include the registration confirmation with closeout submittals. Reference: Nova Durable Tropical Hardwood Warranty (https://www.novausawood.com/PDFs/nova-durable-tropical-hardwood-warranty-2026.pdf).
SPECIFIER NOTEDouglas fir clears are not covered by a manufacturer's warranty for exterior use.
PART 2 - PRODUCTS
2.1MANUFACTURERS
SPECIFIER NOTEChoose ONE of the two options below. Option 1 (basis of design) is recommended for most public and private work: it names Nova while allowing the contractor to propose an equal under Division 01. Use Option 2 (proprietary) only where the Owner permits a sole-source specification.
A.Basis-of-Design Product: Subject to compliance with requirements, provide [Ambara] [Inari] [Korina] [Melywood] [Batu] [Douglas Fir clear] exterior boards by Nova USA Wood Products, Forest Grove, Oregon; www.novausawood.com.
1.Comparable Products: Products of other manufacturers will be considered when they meet every performance requirement of this Section, documented by test reports from independent laboratories, and are approved by the Architect in accordance with Section 01 60 00 - Product Requirements.
2.Substitutions: Not permitted.
B.Source Limitations: Obtain each product type, including clips, fasteners, end sealer and factory finish, from a single source through one manufacturer.
2.2SPECIES
A.Thermally Modified Ayous (Basis of Design: Nova Ambara): Triplochiton scleroxylon, proprietary closed-system thermal modification; A & Better Clear; density 320 kg/m3; swelling less than 1 percent per ASTM D1037; decay Durability Class 1 (very durable) per CEN/TS 15083-1 and "Highly Resistant" per ASTM D1413 / AWPA E10, mass loss 0 to 5 percent; SFM 12-7A-1 listed as wall siding (CSFM BML Listing 8140-2377:0003 (SFM 12-7A-1, Western Fire Center report 25068r2)); Untreated: not rated ASTM E84 Class A or B; not tunnel-tested.
B.Thermally Modified Nordic Spruce (Basis of Design: Nova Inari): Picea abies, ThermoWood Thermo-D (212 deg C); Select Knotty equivalent to WCLIB 111-e, f; density 440 kg/m3; Durability Class 2 per EN 350; Untreated: not rated ASTM E84 Class A or B; not tunnel-tested.
C.Thermally Modified Hardwood (Basis of Design: Nova Korina): Terminalia superba, proprietary closed-system thermal modification; Standard and Better; density 600 kg/m3; MOR 12,510 psi; MOE 1,520,000 psi; Janka 670 lbf; swelling and shrinkage less than 2 percent; durability Class 2 per EN 350 (producer-reported); untreated, not tunnel-tested.
D.Tannin-Free Merbau (Basis of Design: Melywood(R)): Intsia bijuga, tannins neutralized by the producer's proprietary injection process; FAS (equivalent to Standard and Better), mixed grain; density 750 kg/m3; Janka 1,500 lbf; durability Class 1 to 2 per EN 350; 1 x 6 only, S4S E4E or milled to pattern; untreated, not tunnel-tested.
E.Batu / Red Balau (Basis of Design: Nova Batu): Shorea guiso (red balau group); Standard and Better; density 850 kg/m3; Janka 2,000 lbf minimum; ASTM E84 Class A, FSI 25 / SDI 65 (tested as 1-inch decking).
F.Douglas Fir Clears (Basis of Design: Nova Douglas Fir): Pseudotsuga menziesii; VGX(R) 85/15 Clear, fine grain, old growth; kiln dried; not tunnel-tested.
SPECIFIER NOTEDouglas fir is moderately durable. Retain only for protected exterior locations such as covered soffits and porch ceilings, with a maintained finish.
2.3PROFILES
A.Trim and Fascia: S4S, eased edges; nominal [1x2] [1x3] [1x4] [1x6] [1x8] [1x10] [1x12] [5/4x] [2x], dressed to American Softwood Lumber Standard (PS 20) sizes or standard industry practice: 1x nominal = 3/4 inch (19 mm) net; 5/4 nominal = 1 inch (25 mm) net; 2x nominal = 1-1/2 inches (38 mm) net. Net widths: 2 = 1-1/2 in.; 3 = 2-1/2 in.; 4 = 3-1/2 in.; 6 = 5-1/2 in.; 8 = 7-1/4 in.; 10 = 9-1/4 in.; 12 = 11-1/4 in. Lengths 8 to 20 feet (2.4 to 6.1 m), odd and even lengths.
B.Dimensional Tolerance: Net dimensions plus 0 inch, minus 1/16 inch (1.5 mm) at time of manufacture; boards within a production batch plus or minus 1/64 inch (0.4 mm). Dimensions change with moisture content during acclimation.
C.Soffit and Ceiling Boards: Profile per Nova Standard Profiles (www.novausawood.com/standard-profiles; downloadable SVG drawings), lengths [8 to 20 feet, odd and even] [specified lengths, cut to length by manufacturer: ]:
1.[5/8 x 4 Combination Ceiling, 9/16 inch (14 mm) thick, 3-1/8 inch (79 mm) face.]✕
2.[5/8 x 6 Combination Ceiling, 9/16 inch (14 mm) thick, 5-1/8 inch (130 mm) face.]✕
3.[1 x 4 Nickel Gap / Edge V Combination T&G, 3/4 inch (19 mm) thick, 3 inch (76 mm) face.]✕
4.[1 x 6 [Nickel Gap] [Edge V] [Combination] T&G, flat back, 3/4 inch (19 mm) thick, 5 inch (127 mm) face.]✕
5.[1 x 8 [Nickel Gap] [Edge V] T&G, flat back, 3/4 inch (19 mm) thick, 7 inch (178 mm) face.]✕
6.[S4S boards with spaced joints, nominal size as indicated.]✕
7.Profile availability by species: Ambara 1x2 through 2x12; Inari and Korina 1x2 through 2x8 (nominal widths to 8 inches); Melywood 1x6; Batu 1x2 through 2x12; Douglas fir clears 1x2 through 2x12.
D.Moisture Content at Shipment: Tropical hardwood and Douglas fir pattern stock (T&G, ceiling and siding profiles) kiln dried to 10 to 12 percent; tropical hardwood S4S boards 12 to 14 percent; thermally modified wood 6 to 8 percent. Acclimate as specified in Part 1.
2.4FASTENERS AND ACCESSORIES
A.Fasteners: [Type 304] [Type 316] stainless steel trim screws or siding nails, sized for 1-1/4-inch (32 mm) minimum penetration into framing. Predrill tropical hardwoods. Use Type 316 within 20 miles (32 km) of salt water.
B.[Concealed Clips: Nova ExoClad QuickClip for soffit and ceiling boards milled for clip attachment.]✕
C.Soffit Vents: [Continuous] [Strip] vents with insect screen, net free area as indicated.
D.End-Grain Sealer: Nova ExoWax end sealer, applied to all field-cut ends and any field-drilled holes.
2.5FINISH
A.Finish: [Back-prime and seal all faces and edges with ExoShield before installation] [Unfinished, allowed to weather]; finish color: [Clear] [Natural] [Mahogany] [Walnut] [Black Walnut] [Platinum] [Antique Bronze].
PART 3 - EXECUTION
3.1EXAMINATION
SPECIFIER NOTEInadequate acclimation is the most common cause of field problems with solid wood: open joints, cupping and buckling. Retain the acclimation hold point below.
A.Acclimation: Do not begin installation until the Architect has received an Acclimation Record showing average moisture content within 2 percent of the site equilibrium moisture content. Material installed without an Acclimation Record will be rejected.
3.2INSTALLATION
A.Install in accordance with manufacturer's published guides, including "Ambara Siding Installation Guide" (https://www.novausawood.com/PDFs/Ambara-Installation-Guide.pdf) where Ambara is used, current edition at time of bid (guides are revised quarterly).
B.Install plumb, level and true; scribe to adjacent construction; use longest practical lengths; make scarf joints at fascia over supports.
C.Maintain ventilation at soffits as indicated.
D.Seal all field-cut ends with ExoWax immediately after cutting.
3.3CLEANING AND PROTECTION
A.Protect installed work from damage and staining until Substantial Completion.
END OF SECTION